ABSTRACT
A device is described which replaces the standard cable clamp used for positioning of neutron depth probes. With the technique developed, positioning is accomplished by suspending he probe from brass stops affixed to the cable.
Several years experience have demonstrated this technique to be entirely satisfactory, resulting in improvement in precision of probe positioning, as well as in a considerable saving of time.
1 Contribution from the State of California, The Resources Agency, Department of Water Resources.
2 Associate Land and Water Use Analyst, Bakersfield, and Associate Soils Specialist, Sacramento, respectively.
Received for publication May 18, 1966. Accepted for publication July 13, 1966.