SSSAJ Journal of Natural Resources and Life Sciences Education
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published in Soil Sci Soc Am J 56:1384-1391 (1992)
© 1992 Soil Science Society of America
677 S. Segoe Rd., Madison, WI 53711 USA
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (68)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hook, W. R.
Right arrow Articles by Hook, P. B.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Hook, W. R.
Right arrow Articles by Hook, P. B.
Agricola
Right arrow Articles by Hook, W. R.
Right arrow Articles by Hook, P. B.

Remote Diode Shorting Improves Measurement of Soil Water by Time Domain Reflectometry

W. R. Hook, N. J. Livingston* and Z. J. Sun

Dep. of Biology, Univ. of Victoria, P.O. Box 1700, Victoria, BC V8W 2Y2; Canada

P. B. Hook

Dep. of Range Science, Colorado State Univ., Fort Collins, CO 80523

* Corresponding author.

ABSTRACT

We describe a new time domain reflectometry (TDR) technique that increases the reliability of soil water content measurements. Remotely switched shorting diodes in combination with differential detection techniques greatly increase the effective amplitude of problem reflections and significantly reduce background noise. Reliable detection of the two reflections that define the apparent dielectric constant of soil was achieved in all laboratory and field conditions. This, for example, enables measurement of volumetric water content in saline or layered soils and allows the use of long connecting cables. Additionally, increased signal-to-noise ratios should allow the development of significantly less complex and expensive measurement systems. A three-rod probe with a single diode was used to evaluate reflections from the air-soil surface; reflected signal levels were increased 10:1 for short cables and 56:1 for a probe located at the end of a 100-m cable. A three diode probe was employed to demonstrate performance in a simulated layered soil; the correct time of arrival of the reflection from the rod end was readily measured even though the reflection was attenuated by a factor of 2500:1. A strip-line two-segment probe was used to measure water content in two adjacent sand layers, providing a 23:1 signal-to-background noise ratio. For all these probes, waveform subtraction was used to remove virtually all background noise.

Received for publication September 30, 1991.


This article has been cited by other articles:


Home page
Vadose Zone JHome page
T. J. Heimovaara, J. A. Huisman, J. A. Vrugt, and W. Bouten
Obtaining the Spatial Distribution of Water Content along a TDR Probe Using the SCEM-UA Bayesian Inverse Modeling Scheme
Vadose Zone J., November 1, 2004; 3(4): 1128 - 1145.
[Abstract] [Full Text] [PDF]


Home page
Vadose Zone JHome page
M. Persson, D. Bendz, and P. Flyhammar
Time-Domain Reflectometry Probe for Water Content and Electrical Conductivity Measurements in Saline Porous Media
Vadose Zone J., November 1, 2004; 3(4): 1146 - 1151.
[Abstract] [Full Text] [PDF]


Home page
Soil Sci.Home page
C. F. Souza, D. Or, and E. E. Matsura
A Variable-Volume TDR Probe for Measuring Water Content in Large Soil Volumes
Soil Sci. Soc. Am. J., January 1, 2004; 68(1): 25 - 31.
[Abstract] [Full Text] [PDF]


Home page
Soil Sci.Home page
W. R. Hook, T. P. A. Ferre, and N. J. Livingston
The Effects of Salinity on the Accuracy and Uncertainty of Water Content Measurement
Soil Sci. Soc. Am. J., January 1, 2004; 68(1): 47 - 56.
[Abstract] [Full Text] [PDF]


Home page
Vadose Zone JHome page
D. A. Robinson, D. A. Robinson, S. B. Jones, J. M. Wraith, D. Or, and S. P. Friedman
A Review of Advances in Dielectric and Electrical Conductivity Measurement in Soils Using Time Domain Reflectometry
Vadose Zone J., November 1, 2003; 2(4): 444 - 475.
[Abstract] [Full Text] [PDF]


Home page
Vadose Zone JHome page
R. C. Harlow, R. C. Harlow, E. J. Burke, and T. P. A. Ferre
Measuring Water Content in Saline Sands Using Impulse Time Domain Transmission Techniques
Vadose Zone J., August 1, 2003; 2(3): 433 - 439.
[Abstract] [Full Text] [PDF]


Home page
Soil Sci.Home page
G. C. Heathman, P. J. Starks, and M. A. Brown
Time Domain Reflectometry Field Calibration in the Little Washita River Experimental Watershed
Soil Sci. Soc. Am. J., January 1, 2003; 67(1): 52 - 61.
[Abstract] [Full Text] [PDF]


Home page
Soil Sci.Home page
C. Nichol, R. Beckie, and L. Smith
Evaluation of Uncoated and Coated Time Domain Reflectometry Probes for High Electrical Conductivity Systems
Soil Sci. Soc. Am. J., September 1, 2002; 66(5): 1454 - 1465.
[Abstract] [Full Text] [PDF]


Home page
Soil Sci.Home page
C. M. P. Vaz and J. W. Hopmans
Simultaneous Measurement of Soil Penetration Resistance and Water Content with a Combined Penetrometer-TDR Moisture Probe
Soil Sci. Soc. Am. J., January 1, 2001; 65(1): 4 - 12.
[Abstract] [Full Text]


Home page
Soil Sci.Home page
S.D. Logsdon
Effect of Cable Length on Time Domain Reflectometry Calibration for High Surface Area Soils
Soil Sci. Soc. Am. J., January 1, 2000; 64(1): 54 - 61.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
The SCI Journals Agronomy Journal Crop Science
Journal of Natural Resources
and Life Sciences Education
Vadose Zone Journal
Journal of Plant Registrations Journal of
Environmental Quality
The Plant Genome
Copyright © 1992 by the Soil Science Society of America.