SSSAJ Grow Your Career with SSSA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published in Soil Sci Soc Am J 59:329-336 (1995)
© 1995 Soil Science Society of America
677 S. Segoe Rd., Madison, WI 53711 USA
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Evett, S. R.
Right arrow Articles by Matthias, A. D.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Evett, S. R.
Right arrow Articles by Matthias, A. D.
Agricola
Right arrow Articles by Evett, S. R.
Right arrow Articles by Matthias, A. D.

Wall Material and Capping Effects on Microlysimeter Temperatures and Evaporation

S. R. Evett*

USDA-ARS Conservation and Production Research Lab., P.O. Drawer 10, Bushland, TX 79012

A. W. Warrick and A. D. Matthias

Dep. of Soil and Water Science, Univ. of Arizona, Tucson, AZ 85721

* Corresponding author ( sevett{at}asrr.arsusda.gov).

ABSTRACT

The microlysimeter (ML) is useful for measurements of evaporation from soil but questions persist regarding correct ML design. We studied the effects of length and wall material on evaporation and the effects of wall material and capping on ML temperatures. Cylindrical steel and plastic MLs of 10-, 20-, and 30-cm lengths and 8.8-cm o.d. were used in two field experiments on a bare Pima clay loam (fine-silty, mixed, thermic Typic Torrifluvent). Steel MLs significantly underestimated 8-d cumulative evaporation compared with plastic MLs for 20-cm lengths. Steel MLs conducted heat more easily and their surfaces were significantly cooler during the day and warmer at night than either plastic MLs or the adjacent field soil. Capping the bottoms with 0.6-cm-thick plastic disks caused accumulation of heat in the MLs. For plastic MLs, only the 20- and 30-cm lengths were long enough for continuous use for 9 d under our conditions. It was unclear if cumulative evaporation varied with length for steel MLs. We recommend that walls be constructed of material with low thermal conductivity and that end caps be designed to maximize thermal transfer between the soil inside and below the ML. A length of at least 30 cm is recommended if measurements are needed at the same location for several days.


NOTES

Contribution from the USDA-ARS Conservation and Production Research Lab., Bushland, TX.

Received for publication October 21, 1993.


This article has been cited by other articles:


Home page
Vadose Zone JHome page
Q. Zuo, F. Jie, R. Zhang, and L. Meng
A Generalized Function of Wheat's Root Length Density Distributions
Vadose Zone J., February 1, 2004; 3(1): 271 - 277.
[Abstract] [Full Text] [PDF]


Home page
Agron. J.Home page
D. J. Bremer
Evaluation of Microlysimeters Used in Turfgrass Evapotranspiration Studies Using the Dual-Probe Heat-Pulse Technique
Agron. J., November 1, 2003; 95(6): 1625 - 1632.
[Abstract] [Full Text] [PDF]


Home page
Soil Sci.Home page
K.R. Wythers, W.K. Lauenroth, and J.M. Paruelo
Bare-Soil Evaporation Under Semiarid Field Conditions
Soil Sci. Soc. Am. J., September 1, 1999; 63(5): 1341 - 1349.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
The SCI Journals Agronomy Journal Crop Science
Vadose Zone Journal Journal of Plant Registrations
Journal of Natural Resources
and Life Sciences Education
Journal of
Environmental Quality
Copyright © 1995 by the Soil Science Society of America.